hypr2000-banner

Reduce operating costs and give your HT2000 oxygen plasma cutting system a dramatic productivity boost with the quick-disconnect HyPro2000™ retrofit torch.

  • 50% faster cutting speeds than standard HT2000
  • SilverPlus® electrodes improve consumable life by at least 75% over HT2000 standard copper
  • Timesaving quick-disconnect torch design with easy alignment feature

HyPro2000 retrofit torch for HT2000

200 A air with standard copper for HyPro2000

Test preflow
flowrates
Test preflow
flowrates
Material
thickness
(inches)
Arc
voltage
(volts)
Torch-to-work
distance
(inches)
Hypertherm
HyPro2000
cutting speed (ipm)
Initial pierce height
(inches)       Factor%
Pierce
delay
time
(s)
Preflow
02        N2Plasma
02Shield
Air
12% 38% 77% 53 psi 1/4 147 0.075 235 0.150 200 0.30
3/8 161 0.188 150 0.280 150 0.30
1/2 156 0.140 130 0.280 200 0.30
5/8 156 0.115 105 0.230 250 0.50
3/4 157 0.115 80 0.230 250 0.60
7/8 162 0.125 65 0.312 250 0.70
1 163 0.125 55 0.312 250 0.80
1-1/4 170 0.125 32 0.312 250 1.25
1-1/2 179 0.175 22 0.437 250 1.50
1-3/4 185 0.175 15 Edge start
2 192 0.175 10