htpro-2000-retro

Reduce operating costs and give your MAX200 plasma system a dramatic productivity boost with the quick-disconnect HyPro2000™ retrofit torch.

  • 25% faster cutting speeds than standard MAX200
  • 75% longer consumable life, compared to the standard MAX200 copper electrode
  • Timesaving quick-disconnect torch design with easy alignment feature

cht_hypro2000_max200_life_en

200 A air with standard copper for HyPro2000

Plasma gas
(psi)
Test       Run
Air       Air
Shield
gas
(psi)
Air
Material
thickness
(inches)
Arc
voltge
(volts)
Torch-to-work
distance
(inches)
Cutting
speed
ipm)
Initial
pierce height
(inches)     Factor %
Pierce delay
time
(s)
30
(65 SCFH)
48
(65 SCFH)
45
(220 SCFH)
1/41520.041900.123000.4
5/161530.051800.153000.6
3/81550.101200.202000.9
1/21580.131000.262001.2
5/81620.19700.382001.3
3/41650.19600.382001.5
7/81700.19500.382001.7
11750.25350.451802.2
1-1/41780.2525Edge start
1-1/21840.2518
1-3/41920.2510
22010.256